STEAM
Steam Turbines
Condensing, back-pressure, extraction-condensing and extraction-back-pressure machines from 0.5 to 200 MW.
- Inlet steam 1.0 – 16.7 MPa / 535 °C
- 3000 / 3600 / 8000 rpm options
- Biomass, waste heat, WtE and heating duty
Complete turbine packages engineered around your heat balance — for biomass plants, waste-heat recovery, combined heat and power, oil & gas facilities and island grids.
Choose the technology that fits your heat source, fuel and load profile — then let us engineer the package around it.
STEAM
Condensing, back-pressure, extraction-condensing and extraction-back-pressure machines from 0.5 to 200 MW.
GAS
Light and heavy-duty units for simple or combined cycle duty, configured to your site fuel.
RECIP
Diesel, heavy fuel oil, natural gas and dual-fuel engines for peaking, standby and isolated grids.
From continuous biomass duty to fast-start island grids — the package is specified around the operating profile.
Direct-fired or gasified residue with back-pressure and condensing units, sized for combined power and heat revenue.
Discuss a project →District heating for industrial parks, with extraction or back-pressure duty following the heat load curve.
Discuss a project →Flue gas from steel, cement and chemical plants drives HRSG steam turbines or ORC units for captive power.
Discuss a project →Medium-temperature, sub-high-pressure turbines for municipal waste boilers, built for continuous duty.
Discuss a project →Gas turbines driving compressors and engines generating on-site power for remote, fuel-rich locations.
Discuss a project →Paralleled diesel or HFO engines take base load and peaking duty, stabilising weak island networks.
Discuss a project →Typical configuration ranges. Final selection follows heat balance calculation and site conditions.
| Type | Output (MW) | Inlet pressure (MPa) | Inlet temp. (°C) | Speed (rpm) | Typical application |
|---|---|---|---|---|---|
| Condensing | 1 – 200 | 1.0 – 16.7 | 300 – 535 | 3000 / 3600 | Power only, biomass plants |
| Back pressure | 0.5 – 50 | 1.0 – 9.8 | 300 – 535 | 3000 – 8000 | CHP, process steam supply |
| Extraction-condensing | 3 – 100 | 3.4 – 16.7 | 435 – 535 | 3000 / 3600 | Industrial parks with varying heat load |
| Extraction-back pressure | 3 – 50 | 3.4 – 9.8 | 435 – 535 | 3000 / 3600 | Two-stage extraction heating |
| Waste-heat admission | 1 – 30 | 0.6 – 4.0 | Saturated – 450 | 3000 – 8000 | Cement, steel, chemical waste heat |
| Type | Output (MW) | Cycle | Efficiency | Fuel | Typical application |
|---|---|---|---|---|---|
| Light-duty | 1 – 50 | Simple cycle | 30 – 38% | Natural gas / diesel / dual fuel | Distributed generation, oil & gas |
| Heavy-duty | 50 – 300 | Simple cycle | 36 – 42% | Natural gas / dual fuel | Grid peaking, base load |
| Combined cycle | 10 – 450 | GT + HRSG + ST | 52 – 62% | Natural gas | High-efficiency plants, district energy |
| Mobile unit | 1 – 25 | Simple cycle | 28 – 36% | Diesel / natural gas | Emergency power, temporary plants |
| Fuel | Unit output (MW) | Electrical efficiency | Start time | Service interval (h) | Typical application |
|---|---|---|---|---|---|
| Diesel | 0.2 – 10 | 40 – 44% | ≤ 10 s | 12000 – 18000 | Standby power, island grids |
| Heavy fuel oil (HFO) | 2 – 20 | 42 – 46% | ≤ 30 s | 16000 – 24000 | Islands, mining, off-grid plants |
| Natural gas | 0.5 – 10 | 42 – 46% | ≤ 15 s | 20000 – 30000 | Distributed energy, peaking |
| Dual fuel | 0.5 – 12 | 41 – 45% | ≤ 15 s | 18000 – 24000 | Regions with unstable gas supply |
| Biogas / producer gas | 0.2 – 4 | 36 – 42% | ≤ 20 s | 12000 – 16000 | Biogas plants, landfill gas |
* Reference ranges only. Efficiency depends on altitude, ambient temperature, fuel heating value and load factor.
Spare parts, overhauls, retrofits and remote diagnostics keep units running through a 20-year design life.
Thermal calculations from real operating data, with machine, parameter and system recommendations — no oversized scope.
Stocked blades, rotors, seals, control valves and bearings, with emergency air freight support worldwide.
Major overhauls, flow-path upgrades, rotor balancing and control modernisation, on site or in our workshop.
Online monitoring of vibration, temperature and differential expansion with early warning of developing faults.
Our engineers supervise erection, commissioning and grid synchronisation, then hand over operating procedures your team can actually use.
Every stage has defined inputs and deliverables, so the proposal does not go back and forth.
Steam parameters, fuel analysis, load curve, site and ambient conditions.
Heat balance diagram, machine selection and preliminary performance guarantees.
System configuration, general arrangement and scope of supply.
Itemised equipment, spare parts and service pricing with delivery terms.
Witnessed key processes, factory tests, third-party inspection and export packing.
Site supervision, grid synchronisation, performance test and O&M training.
Send steam parameters, fuel type or electrical demand and we will reply within one business day with a preliminary selection and indicative price range.